Function
- Manually-operated directional valve Push-pull detented 3-way 2-position.
Application
- Provides 3-way directional control in hydraulic systems. Panel mount design is ideal for bleed-down of gauge pressures or load-sense pressures on hydraulic test stands and power units.
Pressure
- 500 PSI maximum at ports 2 and 3
- Consult factory for higher operating pressures.
- 50 psi at port 1
Flow
- .5 GPM
Cavity
- Common cavity C08-3
Media Temperature
- -40º to 100º C
Internal Leakage
- 1 cubic inch per minute @ 500 psi
Construction
- Steel, stainless steel, aluminum
- Exposed parts plated
Available Options
Consult Factory for details
- Line Bodies
Seal Kit
- SK8-3
Cartridge Weight
- 0.3 lbs