Function
- Motor driven, variable orifice, restrictive type, hydraulic flow control, non-pressure compensated. Pressure balanced, bi-directional flow.
Operating Pressure
- 3000 psi maximum differential
- Consult factory for higher operating pressures
Flow Ranges
Based on 100 PSI pressure differential with valve fully open. See pressure drop curves for additional application data
- 080 0-80 gpm (Equivalent to Ø.55” orifice at full open)
- 100 0-100 gpm (Equivalent to Ø.60” orifice at full open)
- 120 0-120 gpm (Equivalent to Ø.66” orifice at full open)
- Custom ranges are available upon request
Voltage
- 12 & 24 VDC
Construction
- Cage, body and spool: Steel, exposed parts plated
- Motor housing assembly: Anodized aluminum
- Standard line bodies are aluminum
- Steel bodies are available upon request
Seal Material
- Buna N and polyurethane standard
- Viton optional
Current Draw
- 0.8 amp when powered at 12 volts
- 1.0 amp when powered at 24 volts
Internal Leakage
- 15 cubic inch per minute per 1000 psi
Temperature
- -40 to 120°C