Function
- Motor driven, variable orifice, restrictive type, hydraulic flow control, non-pressure compensated. Pressure balanced, bi-directional flow.
Operating Pressure
- 3000 psi maximum differential
- Consult factory for higher operating pressures
Flow Ranges
Based on 100 PSI pressure differential with valve fully open. See pressure drop curves for additional application data
- 03 0-3 gpm (Equivalent to Ø.14” orifice at full open)
- 05 0-5 gpm (Equivalent to Ø.18” orifice at full open)
- 10 0-10 gpm (Equivalent to Ø.25” orifice at full open)
- 15 0-15 gpm (Equivalent to Ø.31” orifice at full open)
- Custom ranges are available upon request
Voltage
- 12 & 24 VDC
Construction
- Cage, body and spool: Steel, exposed parts plated
- Motor housing assembly: Anodized aluminum
Seal Material
- Buna N and polyurethane standard
- Viton optional
Current Draw
- 0.8 amp when powered at 12 volts
- 1.0 amp when powered at 24 volts
Internal Leakage
- 1 cubic inch per minute per 1000 psi
Temperature
- -40 to 120°C