H10 Manual Flow Control Valve

Function

  • Variable orifice, restrictive type, hydraulic flow control, non-pressure compensated. Pressure balanced, bi-directional flow.
  • 90 degree rotation.
  • Can be used with most of our standard Motorized Flow Control manifold packages

Operating Pressure

  • 3000 psi maximum differential
  • Consult factory for higher operating pressures

Flow Ranges

Based on 100 PSI pressure differential with valve fully open. See pressure drop curves for additional application data

  • 03 0-3 gpm (Equivalent to Ø.14” orifice at full open)
  • 05 0-5 gpm (Equivalent to Ø.18” orifice at full open)
  • 10 0-10 gpm (Equivalent to Ø.25” orifice at full open)
  • 15 0-15 gpm (Equivalent to Ø.31” orifice at full open)
  • Custom ranges are available upon request

Construction

  • Cage, Body and Spool: Steel, exposed parts plated
  • Motor housing assembly: Anodized aluminum
  • Standard line bodies are aluminum
  • Steel bodies are available upon request

Seal Material

  • Buna N and polyurethane standard
  • Viton optional

Internal Leakage

  • 1 cubic inch per minute per 1000 psi

Temperature

  • -40 to 120°C

Cavity

  • C 10-2 industry common cavity

Valve Installation Torque

  • 35 ft-lbs

Cartridge Weight

  • H10 cartridge only 0.8 lbs
  • H10 with aluminum body 1.8 lbs

Seal kit

  • SFP25247

How To Build Your Part Number